Performance evaluation of a 2 MW wind power project
DOI:
https://doi.org/10.17159/2413-3051/2006/v17i4a3232Keywords:
shutdown, power coefficient, system availability, rating power, performanceAbstract
This work is the analysis of the energy generation of a 2 MW wind power project installed at Motha, District Amaravati, in the state of Maharashtra. The various availabilities of the wind power project were studied for the efficient energy production of the project. It was observed that 92.72 percent of the system was available for energy generation throughout the year. The energy generation data with the various shutdowns of the system was studied. The energy generation of the system was studied in terms of the plant load factor or the capacity factor. Capacity factor was observed to be 21.16 percent with the total energy generation unit being 3.73 MWh.Downloads
References
Anonymous 1997. Wind Performance Characteristics.
NWCC Wind Energy Series No. 10, Nation Wind
Coordination Committee, at www.nationalwind.org.
Anonymous 2004. 1 MW Wind Turbine System and
Power Curve. Suzlon Energy Ltd. at www.suzlon.com.
Iniyan, S. L. Suganthi and T.R. Jagedeesan. 1996. Fault
Analysis of Wind Turbine Generators in India WREC
: 772-776.
Iniyan, S. L. Suganthi and A.A. Samuel. 2003. Pareto
Analysis on Grid Problems of Wind Turbine
Generator for Sustainable Development. Wind pro.
: 34-37, Abstracts quoted in TIDEE, 2(1).
MEDA 2001. Annual Report. Maharashtra Energy
Development Agency. Pune: 1-3.
MEDA 2002. News and Events: 2 MW Demonstration
Power Project at Motha Commissioned. Future
Energy. Maharashtra Energy Development Agency,
(2): 31.
Anonymous 1997. Wind Performance Characteristics.
NWCC Wind Energy Series No. 10, Nation Wind
Coordination Committee, at www.nationalwind.org
United Nations (U.N.). 1997. Kyoto Protocol to the
United Nations Framework
Convention on Climate Change, third session Kyoto,
Dec. 1-10, at www.un.org.