Impact of thermoelectric cooling modules on the efficiency of a single-phase asynchronous machine

Authors

  • Rupert Gouws University of Cape Town
  • Heino van Jaarsveldt

DOI:

https://doi.org/10.17159/2413-3051/2014/v25i1a2682

Abstract

In this paper, the authors present the impact of thermoelectric cooling modules (TECMs) on the efficiency of a single-phase asynchronous machine. TECMs are used to lower the stator winding temperature and core temperature of the single-phase asynchronous machine. A similar effect might be possible by operating the asynchronous machine in a controlled lower temperature environment or by using other means of improved controlled cooling. An overview on the materials and method used during the experimental setup of the single-phase asynchronous machine with the TECMs is provided. Experimental results on the efficiency analysis, temperature analysis and equivalent circuit parameter analysis are provided. It is shown that the efficiency of the single-phase asynchronous machine can be increased by 4.44% when cooled by TECMs.

Downloads

Download data is not yet available.

Author Biography

  • Rupert Gouws, University of Cape Town
    Energy Research Centre Snr Research Officer

Downloads

Published

2014-03-23

How to Cite

Impact of thermoelectric cooling modules on the efficiency of a single-phase asynchronous machine. (2014). Journal of Energy in Southern Africa, 25(1), 13-18. https://doi.org/10.17159/2413-3051/2014/v25i1a2682